Compact Infrared Sensors
|
The sensors of the TF series are suitable for use of contact-less measurements of surface temperatures ranging between -32°C and +2,500°C. They are characterised by quick response times, no mechanical wear, and no leakage error.
- high precision thanks to digital signal processing
- can be configured through PC optimally to application
- compact design, robust stainless steel housing
Technical data:
- linear analogue output 4-20mA
- LED pilot light
- up to 70°C ambient temperature
- Test port: max. load 700 O (24V )
- Protection class IP 65 pursuant to DIN 40050
- Maximum value memory: Delete through set time / Automatically for new medium to be measured
- excellent sight ratios
|

Zubehör (optional):
- cooler (stainless steel)
- air purge
- vacuum flange
- mounting angle
- laser pilot light
- Digitalanzeigen
- power pack
|
Specifications:
|
TF 7118-S |
TF 7125-S |
TF 7113-GA |
TF 7118-GA |
TF 7110-T4 |
TF 7112-T5 |
TF 7125-T5 |
TF 7109-1T4 |
| |
|
|
|
|
|
|
|
|
Place of action |
Metal- and Ceramics- industry |
Metal- and Ceramics- industry |
Metal- and Ceramics- industry |
Metal- and Ceramics- industry |
für non-metal surfaces |
for the Glass- industry |
für non-metal surfaces |
für non-metal surfaces |
Measurement range |
650 - 1800°C |
8000 - 2500°C |
300 - 1300°C |
350 - 1800°C |
300 - 1000°C |
100 - 1200°C |
400 - 2500°C |
-32 - 900°C |
Spectral range |
0,8 - 1,1µm |
0,8 - 1,1µm |
1,45 - 1,8µm |
1,45 - 1,8µm |
3,9µm |
5,14µm |
5,14µm |
8 - 14µm |
Distance ratio |
100 : 1 |
150 : 1 |
100 : 1 |
100 : 1 |
40 : 1 |
40 : 1 |
50 : 1 |
50 : 1 |
Accuracy |
0,5% |
0,5% |
0,5% |
0,5% |
0,5% |
0,5% |
0,5% |
0,5% |
Reproducibility |
0,1% |
0,1% |
0,1% |
0,1% |
0,1% |
0,1% |
0,1% |
0,1% |
Set-up time t90 |
20ms |
20ms |
20ms |
20ms |
100ms |
100ms |
100ms |
100ms |
emission ratio |
5 - 100% |
5 - 100% |
5 - 100% |
5 - 100% |
20 - 100% |
20 - 100% |
20 - 100% |
20 - 100% |
Integrated LED |
ja |
ja |
ja |
ja |
- |
- |
- |
- |
Int. MAX value storage |
ja |
ja |
ja |
ja |
- |
- |
- |
- |
Optic device |
I, II, III |
I, IIS, IIIS |
I, II, III |
I, II, III |
IV, V, VI |
IV, V, VI |
IV, V, VI |
VII, VIII, IX |
Power supply |
24V DC ±25% |
24V DC ±25% |
24V DC ±25% |
24V DC ±25% |
24V DC ±25% |
24V DC ±25% |
24V DC ±25% |
24V DC ±25% |
|
Measuring spot M (mm) and distance a (mm)
| Optic |
a = 0 |
600 |
1000 |
1500 |
2000 |
| |
|
|
|
|
|
| Optic I |
13 |
6 |
15 |
26 |
36 |
| Optic II |
16 |
10 |
9 |
15 |
22 |
| Optic III |
17 |
13 |
11 |
11 |
17 |
| |
|
|
|
|
|
| Optic IS |
13 |
4 |
12 |
23 |
34 |
| Optic IIS |
16 |
7 |
5 |
12 |
19 |
| Optic IIIS |
17 |
10 |
7 |
7 |
14 |
Measuring spot M (mm) and distance a (mm)
| Optic |
a = 0 |
100 |
200 |
300 |
| Optic IV |
15 |
2,5 |
18 |
35 |
| |
|
|
|
|
| Optic |
a = 0 |
300 |
600 |
1000 |
| Optic V |
15 |
6 |
22 |
45 |
| Optic |
a = 0 |
1200 |
2500 |
4000 |
| Optic VI |
15 |
24 |
50 |
80 |
| Optic |
a = 0 |
100 |
200 |
300 |
| Optic V II |
15 |
2 |
18 |
35 |
| Optic |
a = 0 |
300 |
600 |
1000 |
| Optic VIII |
15 |
6 |
22 |
45 |
| Optic |
a = 0 |
800 |
1500 |
2500 |
| Optic IX |
15 |
16 |
36 |
68 |
|
Back |
|
|